Product Classification / EMDN Category
FDA Product Code: All lot codes
Directory of devices assigned to product classification code All lot codes.
enforcement
DePuy Mitek FMS Outflow Tubing with One-Way valve Product Code:284649 Product Usage: The Intermediary Tubing for FMS Fluid Management Systems connects the Inflow Tubing to the arthroscopic sheath during arthroscopic procedures. The Polyvinyl Chloride (PVC) tubing integrates several functional components including: luer locks for attaching the tube to the Inflow tubing and sheath, clamps, and a one-way valve. The FMS Outflow Tubing with One-Way valve is sterile and intended for single use with the FMS Fluid Management Systems in a surgical setting by personnel trained in arthroscopy.
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
ORTHOFIX Centurion POCT System Drill Guide PN 69-1010 and PN 69-1012. Drill Guides are used to interface with various drill tips during the drilling procedure of bone preparation.
Manufacturer: Orthofix, Inc
View Specs →
enforcement
Combiset Blood Line with BVM for Hemodialysis use Catalog Number: 03-2965-9. Intended for use as the extracorporeal blood circuit during Hemodialysis and is indicated for use with conventional and high flux negative pressure hemodialyzer equipment.
Manufacturer: Fresenius Medical Care Holdings, Inc.
View Specs →
enforcement
TRUFILL n-Butyl Cyanoacrylate (n-BCA) Liquid Embolic System; Two 1 g tubes of n-BCA, one 10 mL vial of Ethiodized Oil and one 1 g vial of Tantalum Powder Product Code: 631-400; The TRUFILL n-BCA Liquid Embolic System is indicated for the embolization of cerebral arteriovenous malformations (AVMs) when pre-surgical devascularization is desired.
Manufacturer: Codman & Shurtleff, Inc.
View Specs →
enforcement
2008K@ Home Blood lines Combiset True Flow Series for Hemodialysis use Catalog Number: 03-2962-3. Intended for use as the extracorporeal blood circuit during Hemodialysis and is indicated for use with conventional and high flux negative pressure hemodialyzer equipment.
Manufacturer: Fresenius Medical Care Holdings, Inc.
View Specs →
enforcement
Combiset Blood Line Hemodialysis use Catalog Number: 03-2622-3. Intended for use as the extracorporeal blood circuit during Hemodialysis and is indicated for use with conventional and high flux negative pressure hemodialyzer equipment.
Manufacturer: Fresenius Medical Care Holdings, Inc.
View Specs →
enforcement
SpiraLok 5.0mm with Ethibond without needles Product Number: 222964 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 5.0mm with Ethibond and needles Product Number: 222960 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
Screw, fixation, boneProduct Number: 222967 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 5.0mm with Panacryl without needles Product Number: 222965 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 6.5mm with Ethibond without needles Product Number: 222966 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 5.0 w/out Needles with violet and blue Orthocord Product Number: 222986 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 6.5mm with Panacryl and needles Product Number: 222963 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 6.5 w/Needles with violet and blue Orthocord Product Number: 222987 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 5.0mm with Panacryl and needles Product Number: 222961 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 6.5mm with Ethibond and needles Product Number: 222962 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 5.0 w/Needles with Orthocord Product Number: 222968 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 6.5 w/out Needles with violet and blue Orthocord Product Number: 222988 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 5.0 w/out Needles with Orthocord Product Number: 222969 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 5.0 w/Needles with violet and blue Orthocord Product Number: 222985 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 6.5 w/Needles with Orthocord Product Number: 222970 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
SpiraLok 6.5 w/out Needles with Orthocord Product Number: 222971 SPIRALOK Anchors are primarily used to re-attach soft tissue to bone in rotator-cuff repair surgery, but are also indicated for use in the foot/ankle, knee and elbow
Manufacturer: DePuy Mitek, Inc., a Johnson & Johnson Co.
View Specs →
enforcement
Siemens Healthcare ADVIA Centaur CA 19-9 250 Test 10491244 50 Test 10491379 Intended Use The ADVIA Centaur CA 19-9 Assay is an in vitro immunoassay for the quantitative measurement of the CA 19-9 tumor-associated antigen, in human serum, using the ADVIA Centaur and ADVIA Centaur XP systems. This assay is indicated for the serial measurement of CA 19-9 to aid in the management of patients diagnosed with cancers of the exocrine pancreas.
Manufacturer: Siemens Healthcare Diagnostics, Inc
View Specs →
enforcement
Siemens Healthcare ADVIA Centaur Digitoxin (DGTN) 250 Test 09046419 50 Test 08861968 Intended Use For in vitro diagnostic use in the quantitative determination of digitoxin in serum or plasma using the ADVIA Centaur and ADVIA Centaur XP systems.
Manufacturer: Siemens Healthcare Diagnostics, Inc
View Specs →
enforcement
Siemens Healthcare ADVIA Centaur Theophylline 2 (THE02) 250 Test 08838753 50 Test 03009619 Intended Use For in vitro diagnostic use in the quantitative determination of theophylline in serum or plasma using the ADVIA Centaur and ADVIA Centaur XP systems.
Manufacturer: Siemens Healthcare Diagnostics, Inc
View Specs →
enforcement
LeGoo Internal Vessel Occluder 10mL Product Number: 10-1000 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel- 0.5 mL LeGoo with 3 Cannula Pouch Product Number: LG50 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel- 1.0 mL LeGoo w/ no Cannula Product Number: PV-100 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel 1.0 mL Product Number: LG100IT LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel-2.5 mL LeGoo w/ no Cannula Product Number: PV-250 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel-1.0 mL LeGoo with 3 Cannula Pouch Product Number: CS-100 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel-0.5 mL LeGoo with 3 Cannula Pouch Product Number: CS-50 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel-0.25 mL LeGoo with 3 Cannula Pouch Product Number: CS-25 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel-0.5 mL LeGoo w/ no Cannula Product Number: PV-50 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Internal Vessel Occluder 5mL Product Number: 10-0500 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel- 1.0 mL LeGoo with 3 Cannula Pouch Product Number: LG100 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
Atrium Medical 24 Fr Trocar catheter, Sterile Model Number: 8424 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
Manufacturer: Atrium Medical Corporation
View Specs →
enforcement
Atrium Medical 32 Fr Trocar catheter, Sterile Model Number: 8432 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
Manufacturer: Atrium Medical Corporation
View Specs →
enforcement
Atrium Medical 28 Fr Trocar catheter, Sterile Model Number: 8428 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
Manufacturer: Atrium Medical Corporation
View Specs →
enforcement
Siemens Healthcare BR Assay for CA 27.29 250 Test Kits 03896216 50 Test Kit 02419937 Ref Kit (US only) 10340081 Intended Use The ADVIA Centaur BR assay is an in vitro diagnostic test for the quantitative serial determination of cancer antigen CA 27.29 in human serum using the ADVIA Centaur and ADVIA Centaur XP systems. The test is intended for use as an aid in monitoring patients previously treated for Stage II or Stage Ill breast cancer.
Manufacturer: Siemens Healthcare Diagnostics, Inc
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 777-115BT: 5 Pack 15mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 900-115: 5 Pack 15mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Atrium Medical 8 Fr Trocar catheter, Sterile Model Number: 8408 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
Manufacturer: Atrium Medical Corporation
View Specs →
enforcement
Atrium Medical 16 Fr Trocar catheter Model Number: 8416 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
Manufacturer: Atrium Medical Corporation
View Specs →
enforcement
Siemens ADVIA Centaur Vitamin D Total Assay SMN SMN 10699533 (500 test)
Manufacturer: Siemens Healthcare Diagnostics, Inc
View Specs →
enforcement
LeGoo Internal Vessel Occluder .25mL Product Number: 10-0025 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 777-112BT: 5 Pack 12mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 777-110: 5 Pack 10mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 900-130: 5 Pack 30mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 900-120: 5 Pack 20mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 777-120: 5 Pack 20mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Magellan Diagnostics LeadCare and LeadCare II test Kits. Product Usage: The LeadCare Blood Lead Test Kit is for in vitro diagnostic use only. The Test Kit is for the quantitative measurement of lead in fresh whole blood. This product is for professional use only. Sensors and Treatment Reagent of the Test Kit are specific for lead only. Contents of this LeadCare Blood Lead Test Kit must only be used with a LeadCare Analyzer and Blood Lead Testing System.
Manufacturer: Magellan Diagnostics, Inc.
View Specs →
enforcement
Magellan Diagnostics LeadCare Ultra and LeadCare Plus test Kits. Product Usage: The LeadCare Blood Lead Test Kit is for in vitro diagnostic use only. The Test Kit is for the quantitative measurement of lead in fresh whole blood. This product is for professional use only. Sensors and Treatment Reagent of the Test Kit are specific for lead only. Contents of this LeadCare Blood Lead Test Kit must only be used with a LeadCare Analyzer and Blood Lead Testing System.
Manufacturer: Magellan Diagnostics, Inc.
View Specs →
enforcement
Brookstone Heated Body Bean, electrically heated SKU numbers: 734863 (Blue), 734864 (Plum), 734865 (Red). Brookstone 3 in 1 wrap ,SKU734397 (Brown). The Products are liquid filled bean shaped pouches that are electrically heated and then detached from the charger prior to use.
Manufacturer: Brookstone Company, Inc.
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel-2.5 mL LeGoo with 1 Cannula Pouch Product Number: LG250 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Internal Vessel Occluder .5mL Product Number: 10-0050 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
Siemens Healthcare Caps for capillary 140/175 uL, Package count 100 For use with blood collection Multicap glass and Multicap-S plastic capillaries SMN: 10311054 Legacy Part number: 478605
Manufacturer: Siemens Healthcare Diagnostics Inc
View Specs →
enforcement
Siemens Healthcare Caps for capillary 100 uL , Package count 200 For use with blood collection Multicap glass and Multicap-S plastic capillaries SMN: 10311053 Legacy Part number: 478601
Manufacturer: Siemens Healthcare Diagnostics Inc
View Specs →
enforcement
PROFEMUR PLUS CoCr MODULAR NECK, REF: PHAC1254, SIZE LONG, ORIENTATION 8 degree VAR/VAL. 12/14 SLT Taper. Orthopedic hip prosthesis component.
Manufacturer: MicroPort Orthopedics, Inc.
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel 0.5 mL Product Number: LG50IT LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
Siemens Healthcare ADVIA Centaur DHEA-504 (DHEAS) 50 Test 06489701 The ADVIA Centaur DHEAS assay is an in vitro diagnostic immunoassay for the quantitative determination of dehydroepiandrosterone sulfate (DHEAS) in human serum and plasma using the ADVIA Centaur and ADVIA Centaur XP systems
Manufacturer: Siemens Healthcare Diagnostics, Inc
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 900-112: 5 Pack 12mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Atrium Medical 10 Fr Trocar catheter, Sterile Model Number: 8410 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
Manufacturer: Atrium Medical Corporation
View Specs →
enforcement
Atrium Medical 12 Fr Trocar catheter, Sterile Model Number: 8412 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
Manufacturer: Atrium Medical Corporation
View Specs →
enforcement
Gel-E Donut : 92025-A (Extra Small), 92025-B (Small), 92025-C (Medium) and Squishon 2 91033-2. The products are intended to support and cradle a baby's head and/or body.
Manufacturer: Philips Medical Systems, Inc.
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 777-115: 5 Pack 15mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 777-120BT: 5 Pack 20mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
LeGoo Internal Vessel Occluder 2.5mL Product Number: 10-0250 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
Atrium Medical 20 Fr Trocar catheter, sterile Model Number: 8420 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
Manufacturer: Atrium Medical Corporation
View Specs →
enforcement
Siemens Healthcare Caps for capillary 50/60 uL, Package count 200 For use with blood collection Multicap glass and Multicap-S plastic capillaries SMN: 10328655 Legacy Part number: 478527
Manufacturer: Siemens Healthcare Diagnostics Inc
View Specs →
enforcement
Intact Disposable Wands (part of the Intact System) 777-112: 5 Pack 12mm Disposable Product Usage: The Intact Medical disposable wands are intended to provide breast tissue for histologic examination with partial or complete removal of an imaged abnormality and to provide breast tissue for histologic examination with partial removal of a palpable abnormality.
Manufacturer: Medtronic Advanced Energy, LLC
View Specs →
enforcement
LeGoo Endovascular Occlusion Gel 2.5 mL Product Number: LG250IT LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
LeGoo Internal Vessel Occluder 1mL Product Number: 10-0100 LeGoo is a water-soluble, biocompatible polymer with reverse thermo-sensitive properties allowing it to be injected as a soft viscoelastic gel that forms an elastic plug within the vessel. LeGoo is indicated for temporary endovascular occlusion of blood vessels up to 4 mm in diameter below the neck.
Manufacturer: Genzyme Corporation, A Sanofi Company
View Specs →
enforcement
Randox CALCIUM (Ca) COLORIMETRIC METHOD RX DAYTONA PLUS Cat. No. CA 8309 R1, Arsenazo Reagent 4 x 20 ml GTIN: 05055273208368
Manufacturer: Randox Laboratories Ltd.
View Specs →
enforcement
Cook Kwart Retro-Inject Ureteral Stent Set: PRODUCT/CATALOG NUMBER/GPN: 4.7 Fr 003500 G14916; 6.0 Fr 003600 G14836; 7.0 Fr 003700 G14837; 8.0 Fr 003800 G14844; Set with AQ Hydrophilic Coating PRODUCT/CATALOG NUMBER/GPN: 4.7 Fr AQ-003500 G17150; 6.0 Fr AQ-003600 G17151; 7.0 Fr AQ-003700 G17152
Manufacturer: Cook Inc.
View Specs →
enforcement
Randox CALCIUM (Ca) Colorimetric Method RX Series Cat. No. CA 3871, R1. Arsenazo Reagent 9 x 51ml GTIN: 05055273200904
Manufacturer: Randox Laboratories Ltd.
View Specs →
enforcement
Cook Salle Intraoperative Pyeloplasty Stent Set PRODUCT/CATALOG NUMBER/GPN: 4.0 Fr - SIPSF-040018-56-6 G18168 4.0 Fr - SIPSF-040018-59 G32773 4.7 Fr SIPSF-050018-59 G32774
Manufacturer: Cook Inc.
View Specs →
enforcement
Medtronic HVAD Battery, Product Number: 1650, 1650CA-CLIN, 1650DE
Manufacturer: Heartware, Inc.
View Specs →
enforcement
Medtronic HVAD Packaged Monitor, Model Numbers: 1500, 1500AU, 1500DE, 1510US, 1511AR, 1511AU, 1511BR, 1511CA, 1511CH, 1511DE, 1511GB, 1511IL, 1511IN, 1511IT, 1511JP, 1511MY, 1520CLIN-AU, 1520CLIN-DE, 1520CLIN-GB, 1520JP, 1520US, 1521AU, 1521BR, 1521CA, 1521CH, 1521DE, 1521GB, 1521IL, 1521IN, 1521IT, 1521JP, 1521KR, 1521TW, 1521US, 1522CA, 1522CA-CLIN
Manufacturer: Heartware, Inc.
View Specs →
enforcement
Medtronic HVAD Controller, Product Numbers: 1400, 1401, 1401AU, 1401BR, 1401CA, 1401CH, 1401DE, 1401GB, 1401IL, 1401IN, 1401IT, 1401JP, 1401US, 1403US, 1407AR, 1407AU, 1407BR, 1407CA, 1407CA-CLIN, 1407CH, 1407DE, 1407GB, 1407IL, 1407IN, 1407IT, 1407JP, 1407KR
Manufacturer: Heartware, Inc.
View Specs →
enforcement
Power Supply: 1. Medtronic HVAD Controller AC Adapter, Product Numbers: 1425AU, 1425CA, 1425DE, 1425GB, 1425IL, 1425IT, 1425US, 1430AR, 1430AU, 1430CA, 1430CH, 1430DE, 1430GB, 1430IL, 1430IN, 1430IT, 1430JP, 1430US 2. Medtronic HVAD Controller DC Adapter, Product Number: 1440
Manufacturer: Heartware, Inc.
View Specs →